Author/Authors :
Rafiei، M نويسنده Department of Environmental Science, University of Pune, Pune 411007, India , , Gadgil، A.S نويسنده Department of Geography, University of Pune, Pune 411007, India , , Ghole، V.S نويسنده Departmentof Chemistry, University of Pune, Pune 411007, India , , Gore، S.D نويسنده Department of Statistics, University of Pune, Pune 411007, India , , Jaafarzadeh، N نويسنده Ahwaz Jondishapour University of Medical Sciences, Ahwaz, Iran , , Golbabaei، F نويسنده University of Tehran Medical Sciences,Tehran, Iran ,
Abstract :
Air pollutants from iron and steel making operations have historically been an
environmental concern. The factory located at Ahwaz, Iran, has two production lines namely, 630 and
650, which produce iron parallel edge. The objective of the study is to determine indoor respiratory
particulate matter (RPM) and FeO concentrations and their comparison with NIOSH standards. This
is a cross–sectional study of personnel working in different environmental conditions. There were
significant differences in mean concentrations of RPM (P < 0.05) in line 650 but not in line 630 as
compared to NOISH standard (3 mg/m3). The FeO concentrations in line 630 and 650 are significantly
lower than the NIOSH standard (5 mg/m3). There is maximum FeO concentration in station 7 (0.8 mg/
m3), due to remains of iron on the billets. In other words, after cutting the beam by saws, carried out
with water pressure of 150 Bar and immersing in cooling beds, the temperature decreases from 550 °C
to 150 °C. As the result, airborne iron oxide concentrations decrease in the respiratory air zone of
workers. There is maximum RPM concentration in station of Billet rejecter for line 630 (7.645 mg/m3),
because this station carries out peel action on metal. The primary form of RPM is not directly related
to the iron handling but may be related to improper ventilation and exhaust system.