• Title of article

    A modified, filtered, pulsed cathodic vacuum arc implantation and deposition apparatus with the filtering duct working as a second anode

  • Author/Authors

    Guangfu، نويسنده , , Wang and Huixing، نويسنده , , Zhang and Xiaoji، نويسنده , , Zhang and Yuguang، نويسنده , , Wu and Renhe، نويسنده , , Tian، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    4
  • From page
    470
  • To page
    473
  • Abstract
    A modified filtered pulsed cathodic vacuum arc implantation and deposition apparatus with the filtering duct biased positively 30–60 V relative to the cathode has been set up. Pulsed cathodic vacuum arc discharge between the duct and the cathode was observed. As a result of this, the cathode erosion rate and ion intensity at the substrate increased dramatically. The influence of the focusing magnetic field of the MEVVA plasma source as well as the positive bias and the guide magnetic field of the filtering duct on the arc discharge and the duct output were studied. Experimental results show that the output of the duct and the duct current increased with increasing duct potential and increasing arc source focusing magnetic field. It is also shown that the duct current decreased with an increase in the guiding magnetic filed, and 7–8 mT duct magnetic field is the optimum for the duct output.
  • Keywords
    Duct potential , Second anode action , Cathode erosion rate , Duct output , Filtering duct , Cathodic arc
  • Journal title
    Surface and Coatings Technology
  • Serial Year
    2000
  • Journal title
    Surface and Coatings Technology
  • Record number

    1799662