Title of article :
The influence of micro-motion on the tissue differentiation around immediately loaded cylindrical turned titanium implants
Author/Authors :
Duyck، نويسنده , , J. and Vandamme، نويسنده , , K. and Geris، نويسنده , , L. and Van Oosterwyck، نويسنده , , H. and De Cooman، نويسنده , , M. and Vandersloten، نويسنده , , J. and Puers، نويسنده , , R. and Naert، نويسنده , , I.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
9
From page :
1
To page :
9
Abstract :
SummaryObjective m of this study was to evaluate the effect of various degrees of implant displacement on the tissue differentiation around immediately loaded cylindrical turned titanium implants. periments were conducted in repeated sampling bone chambers placed in the tibia of 10 rabbits. Tissues could grow into the bone chambers via perforations. Due to its double structure, tissues inside the chamber could be harvested leaving the chamber intact. This allowed several experiments within the same animal. The chambers contained a cylindrical turned titanium implant that was loaded in a well-controlled manner. In each of the 10 chambers, four experiments were conducted with the following test conditions: immediate implant loading by inducing 0 (control), 30, 60 and 90 μm implant displacement, 800 cycles per day at a frequency of 1 Hz, twice a week during a period of 6 weeks. Histological and histomorphometrical analyses were performed on methylmethacrylate histological sections. An ANOVA was conducted on the dataset. s tal tissue volume was significantly lowest in the unloaded control condition. The bone volume fraction on the other hand, was significantly larger in the unloaded and 90 μm implant displacement, compared to the 30 μm implant displacement. Bone density increased with increasing micro-motion with significantly higher values for the 60 μm- and 90 μm-test conditions compared to the unloaded situation. The chance to have bone-to-implant contact decreased in case of micro-motion at the tissues-implant interface. sion gnitude of implant displacement had a statistically significant effect on the tissue differentiation around immediately loaded cylindrical turned titanium implants. Implant micro-motion had a detrimental effect on the bone-to-implant contact in an immediate loading regimen.
Keywords :
Titanium , animal , Implant , Bone chamber , Immediate loading
Journal title :
Archives of Oral Biology
Serial Year :
2006
Journal title :
Archives of Oral Biology
Record number :
1803425
Link To Document :
بازگشت