Title of article :
Homogeneous boron targeting of heterogeneous tumors for boron neutron capture therapy (BNCT): Chemical analyses in the hamster cheek pouch oral cancer model
Author/Authors :
Heber، نويسنده , , Elisa M. and Trivillin، نويسنده , , Verَnica A. and Nigg، نويسنده , , David W. and Itoiz، نويسنده , , Maria E. and Gonzalez، نويسنده , , Beatriz N. and Rebagliati، نويسنده , , Raْl J. and Batistoni، نويسنده , , Daniel and Kreimann، نويسنده , , Erica L. and Schwint، نويسنده , , Amanda E.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
8
From page :
922
To page :
929
Abstract :
SummaryObjective s a tumour cell targeted radiation therapy. Uniform targeting of heterogeneous tumours with therapeutically effective boron carriers would contribute to a therapeutic effect on all tumour cell populations and avoid radioresistant fractions. This remains an unresolved challenge. The aim of the present study was to evaluate the degree of variation in boron content delivered by boronophenylalanine (BPA), GB-10 (Na210B10H10) and the combined administration of (BPA + GB-10) in different portions of tumour, precancerous tissue around tumour and normal pouch tissue in the hamster cheek pouch oral cancer model. als and methods s of different areas of tumour, precancerous tissue and normal pouch tissue were taken from tumour-bearing hamsters, 3 h post-administration of i.p. BPA (15.5 mg B/kg b.w.), or i.v. GB-10 (50 mg B/kg b.w.), or 3 h and 1.5 h post-administration respectively of i.v. GB-10 (34.5 mg B/b.w.) and sequential i.p. injections of BPA (total dose 31 mg B/kg b.w.) given jointly. Boron content was evaluated by inductively coupled plasma optical emission spectroscopy (ICP-OES). The degree of homogeneity in boron targeting was assessed in terms of the coefficient of variation (V: [S.D./mean] × 100) of boron values. Statistical analysis of the results was performed by one-way ANOVA and the least significant difference test. s and GB-10 plus BPA achieved respectively a statistically significant 1.8- and 3.3-fold increase in targeting homogeneity over BPA. sions mbined boron compound administration protocol contributes to homogeneous targeting of heterogeneous tumours and would be expected to increase therapeutic efficacy of BNCT.
Keywords :
BNCT , ORAL CANCER , Hamster cheek pouch , Boron targeting
Journal title :
Archives of Oral Biology
Serial Year :
2006
Journal title :
Archives of Oral Biology
Record number :
1803790
Link To Document :
بازگشت