Title of article :
Test–retest reliability of electromyographic variables of masseter and temporal muscles in patients with cerebral palsy
Author/Authors :
Giannasi، نويسنده , , Lilian Chrystiane and Matsui، نويسنده , , Miriam Yumi and Politti، نويسنده , , Fabiano and F Batista، نويسنده , , Sandra Regina and Caldas، نويسنده , , Bruna F. and Amorim، نويسنده , , José Benedito O. and de Oliveira، نويسنده , , Luis Vicente Franco and Oliveira، نويسنده , , Claudia Santos and Gomes، نويسنده , , Mônica Fernandes، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
7
From page :
1352
To page :
1358
Abstract :
AbstractIntroduction m of this study was to evaluate the reliability of surface electromyography of the masticatory muscles in patients with cerebral palsy. s e electromyography was performed over the masseter and temporal muscles in 15 patients with cerebral palsy with the mandible at rest and during maximum clenching effort in two sessions. The data were analyzed using the root mean square amplitude, mean frequency, median frequency, zero crossings and approximate entropy. s within-day evaluations, intraclass correlation coefficients were higher (0.80–0.98) for the all electromyography variables and muscles during maximum clenching effort. In the resting position, the coefficients revealed good to excellent reliability (0.61–0.95) for root mean square, mean frequency, median frequency and zero crossings and fair to good reliability (0.53–0.74) for approximate entropy. In the between-day evaluations, the coefficients revealed good to excellent reliability (0.60–0.86) for mean frequency, median frequency, zero crossings and approximate entropy. In the resting position, the coefficients revealed poor to fair reliability (0.23–0.57) for all electromyography variables studied. The root mean square had the highest standard errors during maximum clenching effort (2.37–5.91) and at rest (1.47–6.86). sion requency, median frequency and approximate entropy are the most reliable variables of surface electromyography signals of the masseter and temporal muscles during maximum clenching effort in individuals with cerebral palsy. These measures can be used to evaluate the function and behaviour of the masticatory muscles in this population following oral rehabilitation and surgical oral procedures as well as for the study the physiology of these muscles.
Keywords :
Cerebral palsy , Electromyography , Masticatory muscles , Reliability
Journal title :
Archives of Oral Biology
Serial Year :
2014
Journal title :
Archives of Oral Biology
Record number :
1808863
Link To Document :
بازگشت