This work reports a comparative investigation on tribological performance enhancement induced by nitrogen Plasma Immersion Ion Implantation (PI3) and conventional Nitrogen Ion Implantation (I2) on Ti and Al based alloys. The study has been carried out on the basis of the surface modification produced by both treatment techniques, in terms of the implanted nitrogen in-depth profiles, and its effect on surface hardening and wear resistance increase of the treated samples. the experimental conditions described, PI3 Ti-based alloys treated samples evidenced slightly better tribological performance than those subjected to I2 treatments. In the case of Al alloys, however, PI3 caused strong detrimental modification on the treated samples as revealed in the increase by a factor 100 of its surface roughness. Consequently, different criteria should be deemed in order to establish the adequacy of one or other technique, not only taking into account set up costs but also considering specific applications.