Title of article
Geotechnical Considerations for End-Use of Old Municipal Solid Waste Landfills
Author/Authors
Hyun Il، P نويسنده General Manager, Institute of Technology, Samsung C & T, 23th Fl., Samsung Corp. Bldg. 1321-20, Seocho2-Dong, Seocho-Gu, Seoul, Korea , , Borinara، P نويسنده Assistant Professor, Department of Technology, Illinois State University, Normal, IL 61709 USA , , Hong، K.D نويسنده Principal Researcher, Research Center, KEPRI, KEPCO. Daejon-si, Korea ,
Issue Information
فصلنامه با شماره پیاپی سال 2011
Pages
12
From page
573
To page
584
Abstract
Geotechnical investigations of waste fills are rarely undertaken, and consequently the geotechnical
community has little knowledge of their engineering properties. In this study, a geotechnical testing program
was conducted to evaluate the engineering properties of old municipal solid waste sampled in Whamyung
MSW landfill site, Busan, Korea. The conducted tests included water content, specific gravity, Atterberg
limits, grain-size distribution, compaction, small scale and large scale consolidation, triaxial compression
(CU), and direct shear tests. The Compression Index,
c C , derived from small scale (70mm in diameter) and
large scale (250mm in diameter) one-dimensional consolidation tests was about 0.04 and 0.09, respectively. A
secondary compression coefficient,
? C , appeared to be less dependent on stress level and more dependent
on the aging level. In triaxial compression and direct shear tests, friction angle and cohesion were evaluated as
36~46o
and 25~60 kN/m2
, respectively. The results reported in this study are comparable to those reported in
the literature and obtained from laboratory and field tests.
Journal title
International Journal of Environmental Research(IJER)
Serial Year
2011
Journal title
International Journal of Environmental Research(IJER)
Record number
1814745
Link To Document