Title of article :
Corrosion properties of Fe–24Cr stainless alloy modified by plasma immersion ion implantation in 0.5 M sulfuric acid solution
Author/Authors :
Tjong، نويسنده , , S.C. and Chu، نويسنده , , P.K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
4
From page :
6781
To page :
6784
Abstract :
Ruthenium (Ru) and mixed Ru–Ti ions were implanted respectively into ferritic Fe–24Cr alloy using the plasma immersion ion implantation (PI3) technique. Potentiodynamic and potential-time response measurements were used to characterize the corrosion behavior of Fe–24Cr alloy exposed to a deaerated sulfuric acid solution. The results showed that the ferritic alloy does not passivate in dilute sulfuric acid. However, plasma-implanted Ru ions can induce spontaneous passivation of the alloy exposed to a sulfuric acid solution. X-ray photoelectron spectroscopy (XPS) analysis showed that Ru is incorporated as Ru4+ species in the hydrated chromium oxyhydroxide passive film formed on the Ru-implanted Fe–24Cr alloy.
Keywords :
Plasma immersion ion implantation , Spontaneous passivation , Ruthenium , Ferritic alloy
Journal title :
Surface and Coatings Technology
Serial Year :
2007
Journal title :
Surface and Coatings Technology
Record number :
1816380
Link To Document :
بازگشت