Title of article :
Biomimetic deposition of apatite coatings on micro-arc oxidation treated biomedical NiTi alloy
Author/Authors :
Liu، نويسنده , , Fu and Xu، نويسنده , , Jilin and Wang، نويسنده , , Fuping and Zhao، نويسنده , , Liancheng and Shimizu، نويسنده , , Tadao، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
6
From page :
3294
To page :
3299
Abstract :
The biomedical NiTi alloy was treated by micro-arc oxidation in an electrolytes containing sodium aluminate and sodium hypophosphite at 400 V constant voltages for 30 min. The MAO-treated NiTi has a porous microstructure on its surface and coatings consisting only of the γ-Al2O3 phase. The ceramic coating prepared by micro-arc oxidation is composed of Al, Ti, Ni, O, and P with the atomic concentration of 26.98%, 3.67%, 3.33%, 65.30% and 0.72%, respectively. The MAO-treated NiTi was soaked in a simulated body fluid (1.0SBF) to investigate the biomimetic deposition of apatite on the surface of Al2O3 coated NiTi alloy. It was found that Al2O3 coated NiTi alloy shows an excellent apatite-forming ability after soaking in a simulated body fluid (1.0SBF) for 14 days, while no apatite-forming ability was observed on bared NiTi alloy even though soaking time is up to 28 days.
Keywords :
NiTi alloy , Micro-arc oxidation , Al2O3 coating , Biomimetic coating , apatite
Journal title :
Surface and Coatings Technology
Serial Year :
2010
Journal title :
Surface and Coatings Technology
Record number :
1822574
Link To Document :
بازگشت