Title of article :
Functional magnetic resonance imaging in a stereotactic setup
Author/Authors :
Debus، نويسنده , , Jürgen and Essig، نويسنده , , Marlo and Schad، نويسنده , , Lothar R. and Wenz، نويسنده , , Frederik and Baudendistel، نويسنده , , Klaus and Knopp، نويسنده , , Michael V. and Engenhart، نويسنده , , Rita and Lorenz، نويسنده , , Walter J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
6
From page :
1007
To page :
1012
Abstract :
The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the patients has been immobilized for stereotactic treatment planning either with a self developed stereotactic ceramic frame and bony fixation or with an individual precision mask system made of light cast. It has been shown that this frame does not produce any image distortion. fMRI was performed using a modified FLASH sequence on a conventional 1.5 T MRI scanner with a specially developed linear polarized head coil. The imaging technique used was an optimized conventional 2D and 3D, first order flow rephased, gradient echo sequence (FLASH) with fat-suppression and reduce bandwidth (16–28 Hz/pixel) and TR = 80–120 ms, TE = 60 ms, flip angle = 40°, matrix = 128 × 128, FOV = 150–250 mm, slice-thickness = 2–5 mm, NEX = 1, and a total single scan time for one image of about 7 sec. The motor cortex stimulation was achieved by touching each finger to thumb in a sequential, self-paced, and repetitive manner. Statistical parametric maps based on studentʹs test were calculated. Pixels with a highly significant signal increase (p < 0.001) are overlaid on T1w SE images. The primary motor and sensory cortex could be visualized with this method in all 10 patients that were imaged in this study. Due to tight fixation of the patientʹs skull there have been no motion artifacts. These results show that functional MRI is feasible in an stereotactic set-up with an standard 1.5 T scanner. This is a prerequisite for the exact pre therapeutic assessment of the function of cortical centers.
Keywords :
Magnetic Resonance Imaging , Techniques , functional imaging , treatment planning , Motor cortex stimulation , Stereotactic immobilization
Journal title :
Magnetic Resonance Imaging
Serial Year :
1996
Journal title :
Magnetic Resonance Imaging
Record number :
1829045
Link To Document :
بازگشت