Title of article :
Automatic realignment of time-separated MR images by genetic algorithm
Author/Authors :
Wanschura، نويسنده , , Thorsten and Coley، نويسنده , , David A. and Vennart، نويسنده , , William and Gandy، نويسنده , , Steve، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
5
From page :
313
To page :
317
Abstract :
A simple yet highly efficient artificial intelligence technique utilizing a genetic algorithm is used to register time-separated pairs of MRI data sets. To encourage others to try the approach, the algorithm is presented by way of a simple example to a 2-D data set; it is equally applicable to 3-D data. The technique is reliably found to reduce mismatch in images of the distal-interphalangeal joint from the order of several mm to just 200 μm (one pixel). The method and transformation are general and would be suitable for locating physical changes between any image data sets. We believe the technique to be of use in functional imaging, measurement of disease progression with time (e.g., degradation of cartilage in arthritic disease) and pre/post-surgical studies.
Keywords :
genetic algorithm , registration
Journal title :
Magnetic Resonance Imaging
Serial Year :
1999
Journal title :
Magnetic Resonance Imaging
Record number :
1830056
Link To Document :
بازگشت