Title of article :
Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries
Author/Authors :
Al-Kwifi، نويسنده , , Osama and Emery، نويسنده , , Derek J. and Wilman، نويسنده , , Alan H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
The effects of the increased field strength of 3T on blood vessel contrast in three-dimensional time-of-flight (TOF) MR angiography (MRA) of the intracranial and carotid arteries was evaluated. Bloch equation simulations based on measured longitudinal relaxation times suggested superior blood-to-background contrast might be expected at 3T over 1.5T when using typical 3D TOF MRA parameters. A 15-volunteer study found that 3T was preferable over 1.5T for visualising distal intracranial vessels and the carotid arteries, by providing superior background suppression and excellent fat suppression. The combination of improved background suppression and improved signal-to-noise at 3T, enabled high resolution intracranial 3D TOF MRA with voxel volumes as small as 0.14 mm3 to be acquired.
Keywords :
carotid artery , Intracranial arteries , MR Angiography , Time-of-flight , 3T , high field
Journal title :
Magnetic Resonance Imaging
Journal title :
Magnetic Resonance Imaging