Title of article :
Noncontrast dynamic MRA in intracranial arteriovenous malformation (AVM): comparison with time of flight (TOF) and digital subtraction angiography (DSA)
Author/Authors :
Yu، نويسنده , , Songlin and Yan، نويسنده , , Lirong and Yao، نويسنده , , Yuqiang and Wang، نويسنده , , Shuo and Yang، نويسنده , , Mingqi and Wang، نويسنده , , Bo and Zhuo، نويسنده , , Yan-Yan and Ai، نويسنده , , Lin and Miao، نويسنده , , Xinyuan and Zhao، نويسنده , , Jizong and Wang، نويسنده , , Danny J.J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
9
From page :
869
To page :
877
Abstract :
Digital subtraction angiography (DSA) remains the gold standard to diagnose intracranial arteriovenous malformations (AVMs) but is invasive. Existing magnetic resonance angiography (MRA) is suboptimal for assessing the hemodynamics of AVMs. The objective of this study was to evaluate the clinical utility of a novel noncontrast four-dimensional (4D) dynamic MRA (dMRA) in the evaluation of intracranial AVMs through comparison with DSA and time-of-flight (TOF) MRA. Nineteen patients (12 women, mean age 26.2±10.7 years) with intracranial AVMs were examined with 4D dMRA, TOF and DSA. Spetzler–Martin grading scale was evaluated using each of the above three methods independently by two raters. Diagnostic confidence scores for three components of AVMs (feeding artery, nidus and draining vein) were also rated. Kendallʹs coefficient of concordance was calculated to evaluate the reliability between two raters within each modality (dMRA, TOF, TOF plus dMRA). The Wilcoxon signed-rank test was applied to compare the diagnostic confidence scores between each pair of the three modalities. dMRA was able to detect 16 out of 19 AVMs, and the ratings of AVM size and location matched those of DSA. The diagnostic confidence scores by dMRA were adequate for nidus (3.5/5), moderate for feeding arteries (2.5/5) and poor for draining veins (1.5/5). The hemodynamic information provided by dMRA improved diagnostic confidence scores by TOF MRA. As a completely noninvasive method, 4D dMRA offers hemodynamic information with a temporal resolution of 50–100 ms for the evaluation of AVMs and can complement existing methods such as DSA and TOF MRA.
Keywords :
Intracranial arteriovenous malformation , Dynamic magnetic resonance angiography (dMRA) , Arterial spin labeling (ASL) , angiography
Journal title :
Magnetic Resonance Imaging
Serial Year :
2012
Journal title :
Magnetic Resonance Imaging
Record number :
1833326
Link To Document :
بازگشت