Title of article :
Validating the performance of one-time decomposition for fMRI analysis using ICA with automatic target generation process
Author/Authors :
Yao، نويسنده , , Shengnan and Zeng، نويسنده , , Weiming and Wang، نويسنده , , Nizhuan and Chen، نويسنده , , Lei، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
Independent component analysis (ICA) has been proven to be effective for functional magnetic resonance imaging (fMRI) data analysis. However, ICA decomposition requires to optimize the unmixing matrix iteratively whose initial values are generated randomly. Thus the randomness of the initialization leads to different ICA decomposition results. Therefore, just one-time decomposition for fMRI data analysis is not usually reliable. Under this circumstance, several methods about repeated decompositions with ICA (RDICA) were proposed to reveal the stability of ICA decomposition. Although utilizing RDICA has achieved satisfying results in validating the performance of ICA decomposition, RDICA cost much computing time. To mitigate the problem, in this paper, we propose a method, named ATGP-ICA, to do the fMRI data analysis. This method generates fixed initial values with automatic target generation process (ATGP) instead of being produced randomly. We performed experimental tests on both hybrid data and fMRI data to indicate the effectiveness of the new method and made a performance comparison of the traditional one-time decomposition with ICA (ODICA), RDICA and ATGP-ICA. The proposed method demonstrated that it not only could eliminate the randomness of ICA decomposition, but also could save much computing time compared to RDICA. Furthermore, the ROC (Receiver Operating Characteristic) power analysis also denoted the better signal reconstruction performance of ATGP-ICA than that of RDICA.
Keywords :
FMRI , ROC power analysis , ICA , ATGP
Journal title :
Magnetic Resonance Imaging
Journal title :
Magnetic Resonance Imaging