Title of article
Comparison of the conventional ‘box technique’ with two different ‘conformal’ beam arrangements for prostate cancer treatment
Author/Authors
Magrini، نويسنده , , S.M. and Cellai، نويسنده , , E. and Rossi، نويسنده , , F. and Pertici، نويسنده , , M. and Compagnucci، نويسنده , , A. and Biti، نويسنده , , G.P.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
6
From page
215
To page
220
Abstract
Summary
e.
ntify the possible advantages arising from the use of ‘conformal’ radiotherapy of localized prostate cancer, and to compare the dose distributions obtained with two different ‘conformal’ techniques.
ts and methods.
patients with localized prostate cancer were enrolled in the study. For each patient, three techniques were planned: the standard ‘box technique’ (A), a four-fields ‘conformal’ technique (B), and a 6-fields conformal technique (C). For each of the 36 3D plans, dose-volume histograms (DVH) were obtained, along with the mean, maximum and minimum doses for the clinical and planning target volumes (CTV, PTV) for the rectum, the bladder, and the femoral heads. The resulting data were compared.
s.
rage, the standard technique resulted in the exposure of a significantly larger bladder volume to the higher doses; a similar, but less remarkable difference has been observed for the rectal volume. The coverage of the PTV appears to be significantly more homogeneous with the two conformal techniques.
sions.
sults presented here add to the evidence available in the literature and suggest a possible advantage of both the conformal techniques over the standard ‘box technique’ for the treatment of localized prostate cancer. The 6-field conformal technique does not seem superior to the four field one.
Keywords
conformal radiotherapy , treatment planning , radiothérapie conformationelle , Cancer de prostate , prostate cancer , Dosimétrie
Journal title
Cancer Radiotherapie
Serial Year
1999