• Title of article

    Effects of overexpansion on stentsʹ recoil, symmetry/asymmetry, and neointimal hyperplasia in aortas of hypercholesterolemic rabbits

  • Author/Authors

    Berrocal، نويسنده , , Daniel H. and Gonzلlez، نويسنده , , Germلn E. and Fernلndez، نويسنده , , Alejandro and Perez، نويسنده , , Susana and Wilensky، نويسنده , , Luciana and Morales، نويسنده , , Celina and Grinfeld، نويسنده , , Liliana and Gelpi، نويسنده , , Ricardo J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    8
  • From page
    289
  • To page
    296
  • Abstract
    Background not known whether overexpansion modifies stent recoil, symmetric distribution of struts, and neointimal hyperplasia. ives jectives were (a) to evaluate whether stent overexpansion modifies the geometric configuration of the stent in the arterial wall, (b) to determine the relationship between overexpansion and stent recoil, and (c) to evaluate the relationship between the distribution of struts and neointimal hyperplasia. s tubular stainless steel 316L stents (3.0 and 3.5 mm in diameter) were implanted at 20 and 10 atm, respectively, in the abdominal aorta of New Zealand rabbits fed a hypercholesterolemic diet (1% cholesterol). Sham operations were also performed in seven animals. Eight weeks after implantation or sham operation, an intravascular ultrasound (IVUS) study was performed to measure stent recoil and aid in stent classification (symmetric or asymmetric) according to strut distribution. The degree of injury and neointimal hyperplasia were also evaluated in hematoxylin-eosin stained sections. s mmetry/asymmetry of stents assessed by IVUS, as well as the neointimal hyperplasia, was similar in both groups. Stent recoil was significantly greater in the 3.0-mm stent (overexpanded) group (0.28±0.02 mm), as compared with stent recoil in the 3.5-mm stent group (0.10±0.01 mm, P<.05). The neointimal hyperplasia in histological slices, independent of the implant technique, was predominantly in zones with higher strut concentration as compared with zones with fewer struts. sions overexpansion enhanced stent recoil and did not modify symmetric and asymmetric strut distribution. Neointimal hyperplasia was not modified by the implant technique. Interestingly, significant hyperplasia was observed in locations with greater strut concentration, independent of overexpansion.
  • Keywords
    Rabbits , Stent , Symmetry/asymmetry , recoil
  • Journal title
    Cardiovascular Pathology
  • Serial Year
    2008
  • Journal title
    Cardiovascular Pathology
  • Record number

    1845355