Title of article
Sensations during removal of epicardial pacing wires after coronary artery bypass graft surgery
Author/Authors
Mullin، نويسنده , , Marlene H. and Roschkov، نويسنده , , Sylvia and Jensen، نويسنده , , Louise and Moore، نويسنده , , Gary and Smith، نويسنده , , Alisa، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
5
From page
377
To page
381
Abstract
Background
ocedure that is commonly performed after coronary artery bypass graft surgery is removal of epicardial pacing wires (EPWs). Currently, there is a paucity of information regarding the sensations experienced by patients during this procedure.
ive
ermine the sensations commonly reported by patients during EPW removal.
s
ndary analysis was performed on data sets from 2 previous studies to determine the sensations commonly experienced by patients during EPW removal. The sample consisted of 144 subjects from 2 teaching hospitals.
s
st commonly reported sensation during EPW removal was a “mild to moderate pulling” sensation.
sion
econdary analysis provides important information regarding the sensations most commonly reported by patients during EPW removal. This sensory information could be incorporated into a psycho-educational information intervention to prepare patients for EPW removal.
Journal title
Heart and Lung
Serial Year
2009
Journal title
Heart and Lung
Record number
1859128
Link To Document