Title of article :
Experimental and numerical investigation of localized fire test for high-pressure hydrogen storage tanks
Author/Authors :
Zheng، نويسنده , , Jinyang and Ou، نويسنده , , Kesheng and Hua، نويسنده , , Zhengli and Zhao، نويسنده , , Yongzhi and Xu، نويسنده , , Ping and Hu، نويسنده , , Jun and Han، نويسنده , , Bing، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
Vehicle fires may cause localized fires on on-board high-pressure hydrogen storage tanks. To verify the safety performance of such tanks under localized fire exposure, a localized fire test was proposed in the Global Technical Regulation for Hydrogen Fuel Cell Vehicles. However, practicality and validity of the proposed test still require further verification. In this paper, this new fire test was experimentally investigated using the type 3 tanks. Influences of hydrogen and air as the filling media were studied. A three-dimensional computational fluid dynamics model was developed to analyze the effects of filling pressure and localized fire exposure time on the activation of thermally-activated pressure relief device (TPRD). The experimental results showed that temperature distribution on the tank surface was uneven around the circumference. The rising temperature of internal hydrogen or air contributed little to TPRD activation. The simulation results indicated that TPRD activation time was slightly affected by the variations of the filling pressures, but it increased when the localized fire exposure time was extended.
Keywords :
Localized fire test , Hydrogen storage tank , Pressure relief device , Global Technical Regulation
Journal title :
International Journal of Hydrogen Energy
Journal title :
International Journal of Hydrogen Energy