Title of article
Low cost monitoring system for safe production of hydrogen from bio-ethanol
Author/Authors
Nieto Degliuomini، نويسنده , , L. and Zumoffen، نويسنده , , D. and Basualdo، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
12
From page
13872
To page
13883
Abstract
In this paper a monitoring system is developed to guarantee safety operational conditions for the hydrogen production from bioethanol. The key idea is to detect the most critical faults with the minimum number of sensors. It can be done through a fault detectability index (FDI) which drives to the optimal measurements selection for building a proper monitoring system. The FDI calculation is based on principal component analysis (PCA) model with combined statistics. It takes into account those sensors already selected for control purposes and penalizes the use of new measurement devices. The overall methodology is tested for fifteen failures such as the catalyzer deterioration in the reforming reactor, faults at the fuel cell, sensors and actuators. Hence, the investment cost can be reduced drastically without losing quality of fault detection. The monitoring system with the selected sensors by the FDI performs better than using all the available plant measurements.
Keywords
Optimal monitoring system design , Faults in catalyzers , Faults in fuel cell , Safety hydrogen production
Journal title
International Journal of Hydrogen Energy
Serial Year
2013
Journal title
International Journal of Hydrogen Energy
Record number
1865409
Link To Document