Title of article
Low Pt loading amorphous alloys applied as anodes and the effect of different proton exchange membranes for PEMFCS
Author/Authors
Ruiz، نويسنده , , N. and Pierna، نويسنده , , A.R. and Barroso، نويسنده , , J. and Sanchez، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
7
From page
16269
To page
16275
Abstract
In this work low-loaded platinum bi-metallic amorphous alloys based on Ni59Nb40Pt0.6X0.4 (X = Ru, Sn) were studied as electro-catalytic anodes in PEMFCs. The electro-catalysts were produced by Mechanical Alloying (MA) using a planetary ball-mill during 40 h and used as anodes onto Nafion® (DuPont) perfluorinated membranes (Nafion® 117, Nafion® 115 and Nafion® XL). In addition, two active areas of fuel cells were used namely 9 and 25 cm2. These electro-catalysts were characterized by both physical and chemical techniques, such as Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD) and Energy Dispersive X-ray Spectroscopy (EDX). Concerning the performance towards the Hydrogen Oxidation Reaction (HOR), the results showed that 25 cm2 of active area of fuel cell with Ni59Nb40Pt0.6Ru0.4 alloy and the Membrane Electrode Assembly (MEA) based on the Nafion® 115 membrane exhibited the best catalytic activity (2083.59 A g−1 Pt), while for the Ni59Nb40Pt0.6Sn0.4 catalyst the Nafion® XL membrane was more suitable (1570.82 A g−1 Pt).
Keywords
MEAS , Electro-catalysts , Nafion , PEMFC , Amorphous alloys
Journal title
International Journal of Hydrogen Energy
Serial Year
2013
Journal title
International Journal of Hydrogen Energy
Record number
1866229
Link To Document