Author/Authors :
Wakabayashi، نويسنده , , Ikuko and Itoi، نويسنده , , Eiji and Sano، نويسنده , , Hirotaka and Shibuya، نويسنده , , Yotsugi and Sashi، نويسنده , , Ryuji and Minagawa، نويسنده , , Hiroshi and Kobayashi، نويسنده , , Moto، نويسنده ,
Abstract :
We performed 2-dimensional finite element model analysis to estimate the mechanical environment of the supraspinatus tendon. The geometric shape of the finite element model was determined by magnetic resonance imaging of a normal human shoulder obtained at 0°, 30°, and 60° of abduction, whereas the histologic location of noncalcified and calcified fibrocartilage was determined from a cadaveric specimen. The supraspinatus tendon was pulled proximally with the force of 10 N at 0°, 53 N at 30°, and 115 N at 60° of abduction. The area of high principal stress maximum was observed on the articular side of the supraspinatus tendon, which shifted toward the insertion as the arm was abducted. High stress concentration on the articular side of the supraspinatus tendon near its insertion during arm elevation may explain the frequent occurrence of rotator cuff tears at this site.