Title of article :
In situ diagnostic techniques for characterisation of polymer electrolyte membrane water electrolysers – Flow visualisation and electrochemical impedance spectroscopy
Author/Authors :
A.R. Dedigama، نويسنده , , I. and Angeli، نويسنده , , P. and Ayers، نويسنده , , K. and Robinson، نويسنده , , J.B. and Shearing، نويسنده , , P.R. and Tsaoulidis، نويسنده , , D. and Brett، نويسنده , , D.J.L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
15
From page :
4468
To page :
4482
Abstract :
An optically transparent polymer electrolyte membrane (PEM) water electrolysis cell was studied using a high-speed camera, thermal imaging and electrochemical impedance spectroscopy to examine the relationship between flow and electrochemical performance. The flow regime spans bubble and slug flow, depending on the rate of gas formation (current density) and water feed rate. Electrochemical impedance spectroscopy (EIS) shows that there is a reduction in mass transport limitation associated with the transition to slug flow.
Keywords :
thermal imaging , Printed Circuit Board , Electrochemical impedance spectroscopy , PEM electrolyser , Bubble formation , Two-phase flow
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2014
Journal title :
International Journal of Hydrogen Energy
Record number :
1867694
Link To Document :
بازگشت