Title of article :
Effects of periodically alternating temperatures on performance of single-chamber microbial fuel cells
Author/Authors :
Zhang، نويسنده , , Yaping and Sun، نويسنده , , Jian and Hu، نويسنده , , Yongyou and Wang، نويسنده , , Zhaoyi and Li، نويسنده , , Sizhe، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
7
From page :
8048
To page :
8054
Abstract :
Practical applications of microbial fuel cells (MFCs) for wastewater treatment are usually operated over a wide range of temperature, especially day–night temperature difference. Here, MFCs at alternating temperatures were compared with those at constant temperatures. MFCs at 6/18 °C reached a steady-state voltage of 0.41 ± 0.05 V at 6 °C and 0.36 ± 0.04 V at 18 °C, which were lower than that of MFCs at 18/30 °C (0.42 ± 0.01 V at 18 °C and 0.47 ± 0.02 V at 30 °C). MFCs at 18/30 °C produced the highest power density of 2169 ± 82 mW m−2 at 30 °C, even higher than that of MFCs at constant temperature 30 °C. Moreover, MFCs at 6/18 °C and 18/30 °C obtained a comparable coulombic efficiencies (94.6 ± 5.2%, 83.2 ± 4.1%, respectively) compared with MFCs at constant temperatures (86.3 ± 7.3% at 18 °C and 84.1 ± 5.5% at 30 °C). These results demonstrate that MFCs could be successfully adapted for use under day–night temperature difference conditions.
Keywords :
Microbial fuel cell , Power Generation , STARTUP , alternating temperature
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2014
Journal title :
International Journal of Hydrogen Energy
Record number :
1868400
Link To Document :
بازگشت