Title of article :
Comparison between cine magnetic resonance velocity mapping and first-pass radionuclide angiocardiography for quantitating intracardiac shunts
Author/Authors :
Mohiaddin، نويسنده , , Raad H. and Underwood، نويسنده , , Richard and Romeira، نويسنده , , Leopoldo and Anagnostopoulos، نويسنده , , Constantinos and Karwatowski، نويسنده , , Stefan P. and Laney، نويسنده , , Robert and Somerville، نويسنده , , Jane، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
4
From page :
529
To page :
532
Abstract :
We conclude that first-pass radionuclide angio-cardiography has limited value when measuring Qp/Qs in our group of patients, and that magnetic resonance imaging with velocity mapping is an excellent alternative technique that should be considered, particularly in patients with complex congenital disease and right-to-left shunt, or when poor bolus quality is anticipated.