Author/Authors :
Ghazzal، نويسنده , , Ziyad M.B. and Burton، نويسنده , , Erick and Weintraub، نويسنده , , William S. and Litvack، نويسنده , , Frank and Rothbaum، نويسنده , , Donald A. and Klein، نويسنده , , Larry and King III، نويسنده , , Spencer B.، نويسنده ,
Abstract :
One hundred twenty-five lesions successfully treated with excimer laser coronary angioplasty at 3 centers were analyzed in a central core laboratory using detailed quantitative angiographic analysis. Sixty-seven narrowings had restenosis (≥50% diameter stenosis at restudy). Correlates of restenosis were as follows: baseline diameter stenosis was 79% in the restenosis group versus 71% in the group without restenosis (p = 0.0002), baseline minimal diameter stenosis was 0.55 mm in the restenosis group versus 0.72 mm in the group without restenosis (p = 0.006), final diameter stenosis was 40% in the restenosis group versus 32% in the group without restenosis (p = 0.002), lesion length ≥7 mm was present in 43% of the restenosis group versus 21% in the group without restenosis (p = 0.009), and Thrombolysis in Myocardial Infarction trial flow 0 to 2 was 33% in the restenosis group versus 15% in the group without restenosis (p = 0.025). The strongest multivariate correlate of restenosis was the baseline diameter stenosis (p = 0.003). Whereas most predictors were not controllable, achieving a low residual diameter stenosis that is operator-dependent can favorably influence the restenosis rate.