Title of article :
Myocardial infarction as a complication of new interventional devices
Author/Authors :
Waksman، نويسنده , , Ron and Ziyad Ghazzal، نويسنده , , MB and Baim، نويسنده , , Donald S. and Steenkiste، نويسنده , , Ann R. and Yeh، نويسنده , , Wanlin and Detre، نويسنده , , Katherine M. and King III، نويسنده , , Spencer B. and The NACI Investigators، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
6
From page :
751
To page :
756
Abstract :
Percutaneous transluminal coronary balloon angioplasty has been associated with acute myocardial infarction (MI) as a complication of the procedure. Abrupt closure, distal coronary embolization, intimal dissection, coronary spasm, and acute thrombosis are the principal etiologies. New interventional devices (stent, laser, and atherectomy catheters) have been introduced as alternatives or adjuncts to balloon angioplasty. With use of the New Approaches to Coronary Intervention Registry, the incidence, predictors, and outcome of MI as a complication of using these devices as the primary mode of intervention were studied. There were 3,265 patients from 39 participating centers in the cohort treated with new devices. MI was reported as an in-hospital complication of using new devices in 154 patients (4.7%), including Q-wave MI in 36 patients (1.1%), and non-Q-wave MI in 119 patients (3.6%). MI rates were not significantly different among all patients with devices in the cohort treated with atherectomy (directional, extractional, rotational), laser (AIS, Spectranetics) or the Palmaz-Schatz stent. Multivariate logistic regression showed that post-procedure MI was associated with multivessel disease, high surgical risk, postinfarction angina, and presence of a thrombus prior to the procedure. Prior percutaneous transluminal coronary angioplasty was inversely related to the incidence of MI. When a specific cause of MI could be detected, the main etiologies were: coronary embolus 16.9%, and abrupt closure 27.3%. Other major in-hospital complications were higher in the MI group than the non-MI group: death 7.8% versus 0.8% (p < 0.001), and bypass surgery 13.6% versus 1.7% (p < 0.001). At 1 year, mortality rates remain higher at 12.9% in the MI group versus 4.9% in the non-MI group (p < 0.01). Despite different indications for the use of new devices, they were not predictors for MI with the exception of the rotablator. The incidence of MI (1.1% Q-wave, 3.6% non-Q-wave) was comparable to previously reported rates for balloon angioplasty. The occurrence of MI is associated with an increase in other in-hospital complications and a doubling of 1-year mortality.
Journal title :
American Journal of Cardiology
Serial Year :
1996
Journal title :
American Journal of Cardiology
Record number :
1883721
Link To Document :
بازگشت