Title of article :
Plasma microRNA profiles for bladder cancer detection
Author/Authors :
Adam، نويسنده , , Liana and Wszolek، نويسنده , , Matthew F. and Liu، نويسنده , , Chang-Gong and Jing، نويسنده , , Wang and Diao، نويسنده , , Lixia and Zien، نويسنده , , Alexander and Zhang، نويسنده , , Jitao D. and Jackson، نويسنده , , David and Dinney، نويسنده , , Colin P.N.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
1701
To page :
1708
Abstract :
Background r cancer (BC) is a burdensome disease with significant morbidity, mortality, and cost. The development of novel plasma-based biomarkers for BC diagnosis and surveillance could significantly improve clinical outcomes and decrease health expenditures. Plasma miRNAs are promising biomarkers that have yet to be rigorously investigated in BC. ive ermine the feasibility and efficacy of detecting BC with plasma miRNA signatures. als and methods miRNA was isolated from 20 patients with bladder cancer and 18 noncancerous controls. Samples were analyzed with a miRNA array containing duplicate probes for each miRNA in the Sanger database. Logistic regression modeling was used to optimize diagnostic miRNA signatures to distinguish between muscle invasive BC (MIBC), non-muscle-invasive BC (NMIBC) and noncancerous controls. s y-nine differentially expressed plasma miRNAs (local false discovery rate [FDR] <0.5) in patients with or without BC were identified. Some diagnostically relevant miRNAs, such as miR-200b, were up-regulated in MIBC patients, whereas others, such as miR-92 and miR-33, were inversely correlated with advanced clinical stage, supporting the notion that miRNAs released in the circulation have a variety of cellular origins. Logistic regression modeling was able to predict diagnosis with 89% accuracy for detecting the presence or absence of BC, 92% accuracy for distinguishing invasive BC from other cases, 100% accuracy for distinguishing MIBC from controls, and 79% accuracy for three-way classification between MIBC, NIMBC, and controls. sions tudy provides preliminary data supporting the use of plasma miRNAs as a noninvasive means of BC detection. Future studies will be required to further specify the optimal plasma miRNA signature, and to apply these signatures to clinical scenarios, such as initial BC detection and BC surveillance.
Keywords :
bladder cancer , microRNAs , PLASMA , Diagnostic
Journal title :
Urologic Oncology
Serial Year :
2013
Journal title :
Urologic Oncology
Record number :
1895435
Link To Document :
بازگشت