Title of article :
Potentials and limitations of color M-Mode and tissue Doppler indexes in identifying pseudonormal mitral filling pattern in patients with acute symptoms of heart failure and preserved left ventricular systolic function
Author/Authors :
Arques، نويسنده , , Stephane and Ambrosi، نويسنده , , Pierre Michel Roux، نويسنده , , Emmanuel and Habib، نويسنده , , Gilbert، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
4
From page :
1057
To page :
1060
Abstract :
The aim of this study was to assess the accuracy of flow propagation velocity by color M-mode (Vp) and peak early diastolic mitral annulus velocity by tissue Doppler (Ea) in identifying pseudonormal mitral filling in 25 patients with acute symptoms of heart failure and preserved left ventricular systolic function compared with 25 gender- and age-matched healthy subjects. Although normal velocities for both Vp and Ea were found in 40% of patients, E/Vp and E/Ea ratios were able to differentiate pseudonormal from normal filling irrespective of values for Vp and Ea.
Journal title :
American Journal of Cardiology
Serial Year :
2004
Journal title :
American Journal of Cardiology
Record number :
1897373
Link To Document :
بازگشت