Title of article :
Usefulness of Left Ventricular Systolic Dyssynchrony by Real-Time Three-Dimensional Echocardiography to Predict Long-Term Response to Cardiac Resynchronization Therapy
Author/Authors :
Soliman، نويسنده , , Osama I.I. and Geleijnse، نويسنده , , Marcel L. and Theuns، نويسنده , , Dominic A.M.J. and van Dalen، نويسنده , , Bas M. and Vletter، نويسنده , , Wim B. and Jordaens، نويسنده , , Luc J. and Metawei، نويسنده , , Ahmed K. and Al-Amin، نويسنده , , Aly M. and ten Cate، نويسنده , , Folkert J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
6
From page :
1586
To page :
1591
Abstract :
Real-time 3-dimensional echocardiography (RT3DE) allows simultaneous timing of regional volumetric changes as a net result of longitudinal, radial, circumferential left ventricular (LV) contraction, hence LV systolic dyssynchrony. We sought to examine real-time 3-dimensional echocardiographically derived dyssynchrony for prediction of long-term response to cardiac resynchronization therapy (CRT) in a prospective study. Ninety consecutive patients with heart failure (mean age 60 ± 12 years, 73% men, New York Heart Association class III in 97%) underwent clinical and echocardiographic assessments at baseline and at 12 months after CRT including real-time 3-dimensional echocardiographically derived LV systolic dyssynchrony index. The systolic dyssynchrony index (SDI) was defined as the SD of time to minimum systolic volume of the 16 LV segments, expressed in percent RR duration. CRT response was defined as a >15% decrease in LV end-systolic volume on real-time 3-dimensional echocardiogram. After 12 months of CRT, 68 patients (76%) were responders. Feasibility of the SDI was 94%. An SDI >10% predicted CRT response with good sensitivity (96%), specificity (88%), positive likelihood ratio (8), and negative likelihood ratio (0.05). Patients with an SDI >10% had mean change (−21%, −31%, 39% vs −13%, −10%, 10%) in LV end-diastolic volume, LV end-systolic volume, and LV ejection fraction, respectively, compared with baseline versus patients with an SDI <10% (p <0.01). Mean acquisition and analysis duration of single-patient RT3DE was 8 minutes (range 6 to 13). Interobserver variabilities of LV end-systolic volume and SDI were 5% and 11%, respectively. In conclusion, RT3DE provides accurate identification of reverse volumetric LV remodeling after CRT. From these accurate volumetric data, RT3DE provides more intuitive assessment of dyssynchrony and response to CRT as a simple, reproducible, and fast technique. CRT can be individually tailored using RT3DE and seems very effective in patients with heat failure with real-time 3-dimensional echocardiographic evidence of dyssynchrony.
Journal title :
American Journal of Cardiology
Serial Year :
2009
Journal title :
American Journal of Cardiology
Record number :
1897928