Title of article :
Clinical and Procedural Characteristics of Acute Hemodynamic Responders Undergoing Triple-Site Ventricular Pacing for Advanced Heart Failure
Author/Authors :
Yamasaki، نويسنده , , Hiro and Seo، نويسنده , , Yoshihiro and Tada، نويسنده , , Hiroshi and Sekiguchi، نويسنده , , Yukio and Arimoto، نويسنده , , Takanori and Igarashi، نويسنده , , Miyako and Kuroki، نويسنده , , Kenji and Machino، نويسنده , , Takeshi and Yoshida، نويسنده , , Kentaro and Murakoshi، نويسنده , , Nobuyuki and Ishizu، نويسنده , , Tomoko and Aonuma، نويسنده , , Kazutaka، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
8
From page :
1297
To page :
1304
Abstract :
The advantages of triple-site ventricular pacing (Tri-V) compared to conventional biventricular site pacing (Bi-V) have been reported. We sought to identify the predictors of acute hemodynamic Tri-V responders. Acute hemodynamic studies were performed in 32 patients with advanced heart failure during Tri-V implantation. After the right ventricular (RV) and left ventricular (LV) leads were implanted for a conventional Bi-V system, an additional pacing lead was implanted in the RV outflow tract for Tri-V. The LV peak +dP/dt and tau were measured during AAI, Bi-V, and Tri-V pacing. A Tri-V responder was defined as a patient whose percentage of increase in the peak +dP/dt during Tri-V was >10% compared to of that during Bi-V. The baseline clinical variables and RV outflow tract lead location were analyzed to identify the characteristics of the Tri-V responders. Of the 32 patients, 10 (31%) were classified as Tri-V responders. The LV end-diastolic volume was greater (246 ± 48 vs 173 ± 53 ml, p <0.01), and the RV outflow tract lead was implanted at a greater outflow tract portion (p <0.05) in the Tri-V responders. Multivariate analysis revealed that only the baseline LV end-diastolic volume (per 50-ml greater) predicted the Tri-V response (odds ratio 2.87, 95% confidence interval 1.03 to 8.00, p <0.05). The area under the receiver operating characteristic curve for the LV end-diastolic volume was 0.84 (p <0.01) and an LV end-diastolic volume of >212 ml had a sensitivity of 80% and specificity of 77% to distinguish Tri-V responders. In conclusion, Tri-V provides greater hemodynamic effect for patients with a larger LV end-diastolic volume owing to its resynchronization effects on the LV anterior wall.
Journal title :
American Journal of Cardiology
Serial Year :
2011
Journal title :
American Journal of Cardiology
Record number :
1901486
Link To Document :
بازگشت