Title of article :
Meta-Analysis of Angiographic Versus Intravascular Ultrasound Parameters of Drug-Eluting Stent Efficacy (from TAXUS IV, V, and VI)
Author/Authors :
Escolar، نويسنده , , Esteban and Mintz، نويسنده , , Gary S. and Popma، نويسنده , , Jeffrey and Michalek، نويسنده , , Aleksandra and Kim، نويسنده , , Sang Wook and Mandinov، نويسنده , , Lazar and Koglin، نويسنده , , Joerg and Stone، نويسنده , , Gregg and Ellis، نويسنده , , Stephen G. and Grube، نويسنده , , Eberhard and Dawkins، نويسنده , , Keith D. and Weissman، نويسنده , , Neil J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
6
From page :
621
To page :
626
Abstract :
Both quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) are currently used to assess in-stent restenosis. This study aimed to use standardized imaging and clinical follow-up to compare QCA parameters with several IVUS parameters to evaluate their strengths and weaknesses for detecting in-stent restenosis in a drug-eluting stent population. A subset of patients from the TAXUS IV, V, and VI studies was evaluated. The subset, which included 216 TAXUS-treated patients and 191 bare-metal stent–treated patients, had complete IVUS and QCA performed at baseline and follow-up. As expected, all QCA and IVUS parameters were consistent with less intimal hyperplasia in TAXUS patients than controls. The overall incidence of QCA binary restenosis was 14.0%, which was 9.3% in TAXUS-treated patients and 19% in bare-metal stent–treated patients (p = 0.0008). Regression analysis showed that QCA late lumen loss and percentage of diameter stenosis correlated only moderately with the various IVUS measures of neointimal hyperplasia for the combined group of patients (TAXUS + bare-metal stent), as well as for the TAXUS-treated and bare-metal stent–treated patients separately. However, in general, correlations within the control (bare-metal stent) group tended to be stronger than within the TAXUS group. The strongest correlation was between QCA percentage of diameter stenosis and IVUS percentage of intimal hyperplasia in the overall group and the control group. The strongest IVUS predictor of QCA binary restenosis at 9 months was maximum percentage of intimal hyperplasia, with an overall C = 0.91 and p <0.001. In conclusion, the QCA and IVUS parameters used to evaluate drug-eluting stent efficacy showed a moderate correlation with IVUS percentage of intimal hyperplasia, reliably predicting QCA binary in-stent restenosis.
Journal title :
American Journal of Cardiology
Serial Year :
2007
Journal title :
American Journal of Cardiology
Record number :
1902002
Link To Document :
بازگشت