Tsuchida، نويسنده , , Keiichi and Serruys، نويسنده , , Patrick W. and Bruining، نويسنده , , Nico and Dudek، نويسنده , , Dariusz and Drzewiecki، نويسنده , , Janusz and Banning، نويسنده , , Adrian P. and Zmudka، نويسنده , , Krzysztof and Schiele، نويسنده , , Jean-François and Zhou، نويسنده , , Zheng and Rademaker، نويسنده , , Tessa A.M. and van Es، نويسنده , , Gerrit-Anne and Koglin، نويسنده , , Joerg a، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
9
From page :
607
To page :
615
Abstract :
Late loss has been used as a reliable surrogate end point for evaluation and differentiation of short-term performance of drug-eluting stents. This study investigated the consistency between angiographic and intravascular ultrasound (IVUS) outcomes of late lumen loss (late loss) and neointimal growth to measure restenotic plaque load in TAXUS and bare metal stents. The randomized TAXUS II trial evaluates the polymer-based paclitaxel-eluting TAXUS stent in slow- and moderate-release formulations. Serial angiographic and IVUS analyses were available in 155 event-free patients (bare metal stent, 74; TAXUS stent, 81) after the procedure, at 6 months, and at 2 years. For this subanalysis, quantitative coronary angiographic (QCA) and IVUS measurements were used to derive late loss and neointimal volume. From after the procedure to 6 months, quantitative coronary angiography and IVUS showed matching results for the 2 groups with significant decreases in late loss and neointimal volume in the TAXUS versus the control group. From 6 months to 2 years, QCA and IVUS measurements also showed results similar to those in the control group, demonstrating neointimal compaction over time. However, in the TAXUS group, QCA late loss showed a nonsignificant decrease from 6 months to 2 years, whereas IVUS neointimal volume increased. In conclusion, although QCA and IVUS results were similar over the first 6 months, long-term assessment of changes in restenotic plaque load showed discrepant findings for the TAXUS. These findings suggest the need for critical reevaluation of current end points and the use of more precise techniques to detect lumen and stent boundaries.
Journal title :
American Journal of Cardiology
Serial Year :
2007
Journal title :
American Journal of Cardiology
Record number :
1902757
Link To Document :
بازگشت