Title of article :
Evaluation of XIENCE V Everolimus-Eluting and Taxus Express2 Paclitaxel-Eluting Coronary Stents in Patients With Jailed Side Branches From the SPIRIT IV Trial at 2 Years
Author/Authors :
Forrest، نويسنده , , John K. and Lansky، نويسنده , , Alexandra J. and Meller، نويسنده , , Stephanie M. and Hou، نويسنده , , Liming and Sood، نويسنده , , Poornima and Applegate، نويسنده , , Robert J. and Wang، نويسنده , , John C. and Skelding، نويسنده , , Kimberly A. and Shah، نويسنده , , Aakar and Kereiakes، نويسنده , , Dean J. and Sudhir، نويسنده , , Krishnankutty and Cristea، نويسنده , , Ecater، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
1580
To page :
1586
Abstract :
The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express2 drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express2 implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express2 stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express2 implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express2 devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial.
Journal title :
American Journal of Cardiology
Serial Year :
2013
Journal title :
American Journal of Cardiology
Record number :
1903503
Link To Document :
بازگشت