Title of article :
Characterization of a thermoelectric cooler based thermal management system under different operating conditions
Author/Authors :
Russel، نويسنده , , M.K. and Ewing، نويسنده , , D. and Ching، نويسنده , , C.Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
652
To page :
659
Abstract :
The performance of a thermoelectric cooler (TEC) based thermal management system for an electronic packaging design that operates under a range of ambient conditions and system loads is examined using a standard model for the TEC and a thermal resistance network for the other components. Experiments were performed and it was found that the model predictions were in good agreement with the experimental results. An operating envelope is developed to characterize the TEC based thermal management system for peak and off peak operating conditions. Parametric studies were performed to analyze the effect of the number of TEC module(s) in the system, geometric factor of the thermo-elements and the cold to hot side thermal resistances on the system performance. The results showed that there is a tradeoff between the extent of off peak heat fluxes and ambient temperatures when the system can be operated at a low power penalty region and the maximum capacity of the system.
Keywords :
Thermoelectric cooler , System coefficient of performance , Operating envelope , Thermal management , Sealed electronics
Journal title :
Applied Thermal Engineering
Serial Year :
2013
Journal title :
Applied Thermal Engineering
Record number :
1905023
Link To Document :
بازگشت