Title of article
Investigation of flow and heat transfer for a split air conditioner indoor unit
Author/Authors
Kumluta?، نويسنده , , Dilek and Karadeniz، نويسنده , , Ziya Haktan and Kuru، نويسنده , , Funda، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
11
From page
262
To page
272
Abstract
Split air conditioners (SACs) include complicated components, such as the fin and tube heat exchanger (FTHE) and cross-flow fan (CFF), and their complex interaction needs to be investigated in detail. In this study, a three-dimensional representative thin-section model was introduced for modelling SAC indoor units, and heat transfer and fluid flow analysis was made to determine the characteristics of the device. In addition, the numerical method was examined by comparing the results with the heat transfer capacity experiments and Stereo Particle Image Velocimetry (SPIV) measurements at the outlet section of the device were conducted to compare the velocity distribution. The results showed that the difference between the numerical and experimental studies were within acceptable limits; therefore, the thin-section model for the numerical study is a good assumption for determining the heat transfer and flow characteristics of the SACs.
Keywords
Computational fluid dynamics , Fin and tube heat exchanger , Split air conditioner , Cross-flow fan , Stereo Particle Image Velocimetry
Journal title
Applied Thermal Engineering
Serial Year
2013
Journal title
Applied Thermal Engineering
Record number
1905264
Link To Document