Title of article
Confined and unconfined nucleate boiling under terrestrial and microgravity conditions
Author/Authors
Souza، نويسنده , , R.R. and Passos، نويسنده , , J.C. and Cardoso، نويسنده , , E.M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
7
From page
1290
To page
1296
Abstract
This paper presents experimental results for subcooled nucleated boiling of n-Pentane, under terrestrial and microgravity conditions, on a heating surface facing downward, for different gap sizes and for low and moderate heat fluxes (≤60 kW/m2). The microgravity conditions were obtained from the Maracati II space mission, which involved the launching of the suborbital Brazilian rocket VSB 30. The results under terrestrial conditions showed a decrease in the heat transfer coefficient with a decrease in the gap size. It was observed that the heat transfer coefficient increased with an increase in the liquid temperature. The results obtained under microgravity conditions were compared with those for terrestrial conditions. For the confined case, the experimental data had the same trend. However, for the unconfined case, there was a difference between the data obtained under microgravity and terrestrial gravity conditions.
Keywords
Nucleate boiling , Boiling , microgravity , Bond number , heat transfer
Journal title
Applied Thermal Engineering
Serial Year
2013
Journal title
Applied Thermal Engineering
Record number
1905502
Link To Document