Dudek، نويسنده , , Dariusz and Brener، نويسنده , , Sorin J. and Rakowski، نويسنده , , Tomasz and Dziewierz، نويسنده , , Artur and Abizaid، نويسنده , , Alexandre and Silber، نويسنده , , Sigmund and Yaacoby، نويسنده , , Elad and Dizon، نويسنده , , José M. and Costa، نويسنده , , Ricardo A. and Maehara، نويسنده , , Akiko and Dressler، نويسنده , , Ovidiu and Stone، نويسنده , , Gregg W.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
5
From page :
1485
To page :
1489
Abstract :
The ability of stent implantation to improve indexes of reperfusion may depend on the time to reperfusion in acute ST-segment elevation myocardial infarction (STEMI) and may also vary with stent type. The purpose of this prespecified analysis from the randomized MGUARD for Acute ST Elevation Reperfusion trial was to evaluate the impact of delay to reperfusion on outcomes in patients with STEMI undergoing primary percutaneous coronary intervention with the MGuard embolic protection stent or standard metallic stents. A total of 431 patients were divided according to symptom-onset-to-balloon time (SBT) into 2 groups: SBT ≤3 hours (167 patients; 39%) and SBT >3 hours (264 patients; 61%). Complete ST-segment resolution (STR) after percutaneous coronary intervention was more often achieved in patients with shorter SBT (58.6% vs 47%, p = 0.02). At 1 year, the all-cause mortality rate was lower in patients with shorter SBT (0% vs 3.5%, p = 0.02). STR was achieved in 58% of MGuard patients and in 45% of the control stent patients (p = 0.008). STR was 57% in the MGuard group versus 38% in the control group (p = 0.002 for SBT >3 hours) and 60% versus 57% (p = 0.72), respectively, for SBT ≤3 hours (p for interaction = 0.11). In conclusion, longer delay to mechanical reperfusion remains an important factor negatively influencing outcomes in patients with STEMI. Use of the MGuard embolic protection stent compared with conventional metallic stents resulted in superior rates of complete STR, even in patients with longer delays to reperfusion.
Journal title :
American Journal of Cardiology
Serial Year :
2014
Journal title :
American Journal of Cardiology
Record number :
1906200
Link To Document :
بازگشت