Title of article :
An indoor experimental investigation of the thermal performance of a TPLT-based natural circulation steam generator as applied to PTC systems
Author/Authors :
Zhang، نويسنده , , Liang and Fan، نويسنده , , Liwu and Hua، نويسنده , , Meng and Zhu، نويسنده , , Ziqin and Wu، نويسنده , , Yuyue and Yu، نويسنده , , Zitao and Hu، نويسنده , , Yacai and Fan، نويسنده , , JianRen and Cen، نويسنده , , Kefa، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
11
From page :
330
To page :
340
Abstract :
An indoor experimental setup of a two-phase loop thermosyphon (TPLT)-based natural circulation steam generator, as applied to parabolic trough solar collector for medium temperature steam generation was proposed. Thermal performance of the TPLT steam generation system, especially the receiver, was investigated experimentally. Relatively low two–phase heat transfer coefficients, 263.03 and 265.03 W/m2 K for two selected steam discharging pressures, were obtained in the receiver for such horizontally-arranged TPLT system. Two types of flow instability, i.e., backflow and bi-directional flow, were observed in the TPLT system. The effects of flow instability on thermal performance of the TPLT steam generation system were analyzed. The results showed that isothermality of the system could be improved due to the presence of both unstable flow conditions. The improved isothermality, however, finally resulted in a lower thermal efficiency. At the steam discharging pressure of 0.15 MPa, heat transfer coefficient was increased by 20.07% and was decreased by 0.40% for the bi-directional flow and backflow patterns, respectively.
Keywords :
Natural circulation steam generator , Thermal Performance , Two-phase loop thermosyphon , Flow instability , Parabolic trough collector
Journal title :
Applied Thermal Engineering
Serial Year :
2014
Journal title :
Applied Thermal Engineering
Record number :
1906479
Link To Document :
بازگشت