Title of article :
Calibration of a capacitive void fraction sensor for small diameter tubes based on capacitive signal features
Author/Authors :
De Kerpel، نويسنده , , Kathleen and Ameel، نويسنده , , Bernd and De Schampheleire، نويسنده , , Sven and TʹJoen، نويسنده , , Christophe and Canière، نويسنده , , Hugo and De Paepe، نويسنده , , Michel، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
7
From page :
77
To page :
83
Abstract :
In this paper, calibration of a capacitive void fraction sensor for small diameter tubes based on capacitive signal features is proposed. Existing calibration methods require the mass flux and vapour quality to be known, which poses serious issues for practical applications. In this work an alternative calibration technique is proposed, based on the statistical parameters of the measurement signal. oposed method was applied to 270 measurement points. The inner tube diameter for all these points is 8 mm, the mass flux ranges from 200 to 500 kg/m²s and the vapour quality ranges between 2.5% and 97.5%. Refrigerants R134a and R410A were used. A good agreement was found, the results were compared to the Steiner version of the Rouhani–Axelsson drift flux void fraction model. The maximum average difference between the model and the predicted value was 1.3% with a standard deviation of 4%.
Keywords :
capacitance , Statistical Parameters , Void fraction , Refrigerant , Flow regime
Journal title :
Applied Thermal Engineering
Serial Year :
2014
Journal title :
Applied Thermal Engineering
Record number :
1906615
Link To Document :
بازگشت