    Influence from the rotating speed of the windward axial fans on the performance of an air-cooled power plant

  • Author/Authors

    He، نويسنده , , Weifeng and Dai، نويسنده , , Yiping and Han، نويسنده , , Dong and Yue، نويسنده , , Chen and Pu، نويسنده , , Wenhao، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    10
  • From page
    14
  • To page
    23
  • Abstract
    The performance of the fan array in the air-cooled steam condensers (ACSCs), which consumes a large amount of the power from the generator, always affects the characteristics of the whole power plant under the effect of the meteorological conditions. As a result, it is significant to optimize the fan mode to obtain a maximum operation efficiency of the air-cooled thermal system. In the paper, a 2 × 600 MW power plant is modeled to investigate the influence from the fan rotating speed on the performance of the fan array as well as the whole air-cooled power plants. It is found that the promotion of the fan rotating speed of the windward fans improves the performance of the fan array and the heat transfer characteristics of the exchangers in the air-cooled steam condenser, and the beneficial net power in consideration of the fan consumption is also raised effectively with an improved thermal efficiency of the closed Rankine cycle.
  • Keywords
    Rotating speed , Fan consumption , Thermal efficiency , Air-cooled steam condenser , Meteorological conditions
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2014
  • Journal title
    Applied Thermal Engineering
  • Record number