Title of article :
Micro gas turbine cogeneration system with latent heat storage at the University: Part I: Plan and energy flow test
Author/Authors :
Kurata، نويسنده , , Osamu and Iki، نويسنده , , Norihiko and Matsunuma، نويسنده , , Takayuki and Maeda، نويسنده , , Tetsuhiko and Hirano، نويسنده , , Satoshi and Kadoguchi، نويسنده , , Katsuhiko and Takeuchi، نويسنده , , Hiromi and Yoshida، نويسنده , , Hiro، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
Overcoming the spatiotemporal mismatch between heat and electricity utilization is a major issue in distributed energy systems. Latent heat storage systems are able to store heat for a long period of time with little heat loss. The Energy Technology Research Institute (ETRI) of the National Institute of Advanced Industrial Science and Technology (AIST) demonstrated a micro gas turbine cogeneration system with latent heat storage at Sapporo City University. Since there had been no cogeneration system with the latent heat storage under service condition, this system was the first demonstration and its characteristic was very important. The proper use of the latent heat storage system will save energy economically, store high energy density, reduce exhaust emissions, and save operational costs.
tent heat storage system operated well and was able to repeat 407 cycles of heat storage and heat release. The efficiency of the electricity generation was about 20%, although the efficiency of the total system remained at 55%, which was lower than the nominal specifications. Heat loss, which amounted to 45%, was from a decrease in the efficiency of the heat exchanger, piping loss around the heat exchanger, heat loss due to cooling of auxiliary equipment, and heat loss due to exhaust gas out of the building. Heat loss of the heat exchanger system and piping loss can be diminished by making better use of the highly sophisticated system. The proper solution is to operate the system for more than 4 h until sufficient heat is stored in the latent heat storage system. This would decrease the heat loss from both the heat exchanger system and the piping.
t II [1], an irregular charge case of the latent heat storage system was discussed when the prime mover of the system was operated at a part load and thermal priority mode. A highly sophisticated system design that solves these problems was necessary for extending the latent heat storage system.
t III [2], a temperature control schedule of the system was demonstrated in winter morning using a new programmable logic controller (PLC). If the more larger latent heat storage system will be developed in the future, it will be expected greatly that the temperature of the classrooms are kept more comfortable with less energy consumptions and less CO2 emission.
Keywords :
Micro Gas Turbine , Latent heat storage , Phase-change material , UNIVERSITY , Pitot tube , Hot Wire Anemometer , heat loss , Energy flow , Cogeneration system
Journal title :
Applied Thermal Engineering
Journal title :