Title of article
Numerical study of performance of wire mesh mist eliminator
Author/Authors
Kouhikamali، نويسنده , , R. and Noori Rahim Abadi، نويسنده , , S.M.A. and Hassani، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
9
From page
214
To page
222
Abstract
In this paper the effects of geometry and operating conditions on the pressure drop and separation efficiency of wire mesh mist eliminator have been investigated numerically. The effects of various variables such as vapor velocity (1–20 m/s), packing density (100–250 kg/m3), demister thickness (300–200 cm), wire diameter (0.1–0.3 mm), diameter of captured droplets (1–3 mm) and the geometry of wires on droplet separation efficiency and vapor pressure drop of demister have been studied in order to evaluate the demister performance. The results show the increase of separation efficiency with increasing the diameter of water droplets, vapor velocity, packing thickness and density while increasing wire diameter decreases the performance.
Keywords
Droplet separation , Wire mesh , Pressure drop , Numerical simulation
Journal title
Applied Thermal Engineering
Serial Year
2014
Journal title
Applied Thermal Engineering
Record number
1907263
Link To Document