Title of article
MFC-cascade stacks maximise COD reduction and avoid voltage reversal under adverse conditions
Author/Authors
Ledezma، نويسنده , , Pablo and Greenman، نويسنده , , John and Ieropoulos، نويسنده , , Ioannis، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
8
From page
158
To page
165
Abstract
Six continuous-flow Microbial Fuel Cells (MFCs) configured as a vertical cascade and tested under different electrical connections are presented. When in parallel, stable operation and higher power and current densities than individual MFCs were observed, despite substrate imbalances. The cascading dynamic allowed for a cumulative COD reduction of >95% in approximately 5.7 h, equivalent to 7.97 kg COD m−3 d−1. Under a series configuration, the stack exhibited considerable losses until correct fluidic/electrical insulation of the units was applied, upon which the stack also exhibited superior performance. In both electrical configurations, the 6MFC system was systematically starved for up to 15 d, with no significant performance degradation. The results from the 14-month trials, demonstrate that cascade-stacking of small units can result in enhanced electricity production (vs single large units) and treatment rates without using expensive catalysts. It is also demonstrated that substrate imbalances and starvation do not necessarily result in cell-voltage reversal.
Keywords
Microbial fuel cells , Wastewater treatment , Voltage reversal , stacking
Journal title
Bioresource Technology
Serial Year
2013
Journal title
Bioresource Technology
Record number
1932071