Title of article :
Performance of a semi-pilot tubular microbial electrolysis cell (MEC) under several hydraulic retention times and applied voltages
Author/Authors :
Gil-Carrera، نويسنده , , L. and Escapa، نويسنده , , A. and Carracedo، نويسنده , , B. and Morلn، نويسنده , , A. and Gَmez، نويسنده , , X.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
63
To page :
69
Abstract :
The influence of applied voltage and hydraulic retention time on the performance of a semi-pilot modular tubular wastewater-fed microbial electrolysis cell (MEC) with high scalability was investigated. A chemical oxygen demand (COD) removal efficiency of 80%, as well as an energy consumption of 0.3–1.1 Wh g-COD−1 removed, were achieved. Hydrogen production was limited by the reduced amounts of organic matter fed into the reactor, the poor performance of the cathode, and COD consuming by non electrogenic microorganisms. The presence of COD consuming microorganism that do not contribute to electrogenic metabolism severely affected the MEC performance.
Keywords :
Domestic wastewater , Hydrogen production , Microbial electrolysis cell (MEC)
Journal title :
Bioresource Technology
Serial Year :
2013
Journal title :
Bioresource Technology
Record number :
1933946
Link To Document :
بازگشت