Title of article :
Method development and validation for isoflavones quantification in coffee
Author/Authors :
Alves، نويسنده , , R.C. and Almeida، نويسنده , , I.M.C. and Casal، نويسنده , , S. and Oliveira، نويسنده , , M.B.P.P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
6
From page :
914
To page :
919
Abstract :
This paper reports the development and validation of an analytical method to quantify three isoflavones (daidzein, genistein and formononetin) in coffee beans and coffee brews, by HPLC with diode-array detection. The aglycones were released by methanolic acid hydrolysis in the presence of the antioxidant BHT and the internal standard 2′-methoxyflavone. The method showed high correlation coefficients (r > 0.999) for standards subjected to the entire procedure. For samples, good intra- and inter-day precisions (<8%), and accuracies (recoveries of 95 ± 1% for ground coffee and 92 ± 2% for coffee brew) were achieved. Detection and quantification limits ranged from 5 to 8 ng/mL and from 14 and 25 ng/mL, respectively. The proposed method proved to be sensitive, precise and accurate.
Keywords :
Hydrolysis , HPLC , Isoflavones , Genistein , Formononetin , Daidzein , Coffee , Diode-array