• Title of article

    Ionic strength-sensitive pullulan acetate nanoparticles (PAN) for intratumoral administration of radioisotope: Ionic strength-dependent aggregation behavior and 99mTechnetium retention property

  • Author/Authors

    Park، نويسنده , , Keun-Hong and Song، نويسنده , , Ho-Chun and Na، نويسنده , , Kun and Bom، نويسنده , , Hee-Seung and Lee، نويسنده , , Kwang Hee and Kim، نويسنده , , Sungwon and Kang، نويسنده , , Dongmin and Lee، نويسنده , , Don Haeng Lee، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    8
  • From page
    16
  • To page
    23
  • Abstract
    In order to design an effective intratumoral radioisotope carrier, a self-assembled nanoparticle evidencing ionic strength (IS)-sensitivity from a polysaccharide derivative (pullulan acetate nanoparticle (PAN)) was prepared via dialysis. The PAN had a spherical shape in a range of size of 50–130 nm and a low critical aggregation concentration (CAC) (<8 μg/mL). With increases in the IS of the dialysis media (ISdia), the CAC of PAN was reduced gradually and the rigidity of the hydrophobic core in PAN was increased. This suggests that the property of PAN was altered more hydrophobically at high IS values. The stabilities of PANs prepared from various ISdia were also monitored with changes in the turbidity and particle size in different IS solutions. In the case of PAN prepared at an ISdia = 0.0, the turbidity was dramatically reduced with increasing IS due to the facilitation of aggregation between the particles, whereas in the other cases, these changes were negligible. This finding indicates that PAN prepared in distilled water (IS = 0.0) can be readily injected as the consequence of its nano-size, and accumulates quickly, then remains in the tumor site for a considerable period (IS = 0.15). In order to closely estimate the potential of PAN as a radioisotope carrier, the radioisotope labeling efficiency of PAN with no chelating agents was evaluated. PAN evidenced a high degree of 99mTechnetium (99mTc) labeling efficiency (approximately 98%). The percentage retention rate (%RR) of the 99mTc-labeled PAN was significantly longer than that of the free 99mTc (p < 0.05), due largely to PANʹs IS-sensitivity. In conclusion, PAN may constitute a new approach to the achievement of maximal radioisotope efficiency with regard to intratumoral administration.
  • Keywords
    99mTechnetium (99mTc) , Intratumoral delivery , Pullulan acetate nanoparticle (PAN) , Ionic sensitivity , radioisotope
  • Journal title
    Colloids and Surfaces B Biointerfaces
  • Serial Year
    2007
  • Journal title
    Colloids and Surfaces B Biointerfaces
  • Record number

    1968380