Title of article :
Optimisation for subcritical fluid extraction of 17-methyltestosterone with 1,1,1,2-tetrafluoroethane for HPLC analysis
Author/Authors :
Han، نويسنده , , Yuqian and Ma، نويسنده , , Qinchuan and Lu، نويسنده , , Jie and Xue، نويسنده , , Yong and Xue، نويسنده , , Changhu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
6
From page :
2988
To page :
2993
Abstract :
A simple, rapid and sensitive method was developed for determination of 17α-methyltestosterone in aquatic products by extraction with subcritical 1,1,1,2-tetrafluoroethane (R134a) extraction and high performance liquid chromatography (HPLC). Response surface methodology (RSM) was adopted to optimise extraction pressure, temperature and co-solvent volume. The optimum extraction conditions predicted within the experimental ranges were as follows: pressure 5 MPa, temperature 31 °C, and co-solvent volume 3.35 ml. The analysis was carried out on XDB-C18 column (4.6 mm × 250 mm, 5 μm) with the mobile phase acetonitrile–water (55:45, v/v), flow rate 0.8 ml/min, temperature 30 °C and wavelength 245 nm. Good linearity of detection was obtained for 17α-methyltestosterone between concentrations of 50–250 ng/ml, r2 = 0.999. The method was validated using samples fortified with 17α-methyltestosterone at levels of 10, 30 and 50 ng/g, the mean recovery exceeds 90%, and the RSD values were less than 10%.
Keywords :
Determination , 17?-methyltestosterone , Subcritical R134a extraction , Aquatic products
Journal title :
Food Chemistry
Serial Year :
2012
Journal title :
Food Chemistry
Record number :
1971404
Link To Document :
بازگشت