گوگجو، موداسير بشير نويسنده Division of Veterinary Surgery, Indian Veterinary Research Institute, Izatnagar, 243122, India Gugjoo, M. B , حقو، مزمل نويسنده Division of Veterinary Surgery, Indian Veterinary Research Institute, Izatnagar, 243122, India Hoque, M , ساكسنا، آبهيشك چاندرا نويسنده Division of Veterinary Surgery, Indian Veterinary Research Institute, Izatnagar, 243122, India Saxena, A. C , شمسوز زاما، مالك محمد نويسنده Division of Veterinary Surgery, Indian Veterinary Research Institute, Izatnagar, 243122, India Shamsuz Zama, M. M , دي، صاحدب نويسنده Division of Medicine, Indian Veterinary Research Institute, Izatnagar, 243122, India Dey, S
Issue Information :
فصلنامه با شماره پیاپی 49 سال 2014
Abstract :
از آنجايي كه در سگها تفاوت ساختار بدن و قفسه سينه باعث محدوديت استفاده از اطلاعات يك نژاد در بقيه نژادها ميشود، مقادير استاندارد به صورت اختصاصي براي يك نژاد گزارش شده است. لابرادور رتريورها از سگهاي شكاري مشتق شدهاند و مقادير اكوكارديوگرافي آنها ممكن است با دامنه طبيعي استاندارد بقيه سگها متفاوت باشد. بنابراين هدف مطالعه حاضر تعيين دامنه مرجع اكوكارديوگرافي مد حركت در سگهاي لابرادور رتريور و بررسي اثر وزن بدن و جنس بر اين پارامترها ميباشد. اطلاعات به دست آمده با اطلاعات بقيه نژادها نيز مقايسه شدند. سگهاي لابرادور رتريور هوشيار و از نظر كلينيكي سالم (تعداد=24) از هر دو جنس براي مطالعه انتخاب شدند. تمام اندازهگيريها از نماي طولي كنار جناغي راست، مسير خروجي بطن چپ انجام شدند و پارامترهاي اندازهگيري شده شامل: ابعاد بطن چپ، عملكرد بطن چپ، حجم بطن چپ، اندازه دهليز چپ و ريشه آئورت و پارامترهاي دريچه ميترال بودند. اطلاعات به دست آمده با پارامترهاي موجود ساير نژادهاي سگ نيز مقايسه شد. ارتباط معنيدار (P<0.05) با وزن بدن در مورد بعضي از پارامترهاي بطن چپ، دهليز چپ و دريچه ميترال مشاهده شد كه در مورد LAD، AOD، LVIDd، LVIDs، IVSd و IVSs (r>0.5) اين ارتباط قوي، در مورد LVPWd، LVPWs، EPSS، EF Slope و SV (r=0.3 to 0.5) ارتباط متوسط و در مورد EDV و ESV (r<0.3) ارتباط ضعيفي وجود داشت. هيچ ارتباط معنيداري بين جنس و پارامترهاي اكوكارديوگرافي ديده نشد. با اين حال بعضي از پارامترها اثر نژادي معنيداري داشتند. انتظار ميرود كه اطلاعات به دست آمده در جهت پيشرفت مطالعات بر روي كارديولوژي دام كوچك با ارزش باشند.
Abstract :
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode echocardiographic reference ranges in Labrador Retriever dogs and to evaluate the effect of body weight and gender on these parameters. The data obtained were also compared with that of the other dog breeds. Conscious clinically healthy Labrador Retriever dogs (n=24) of both sexes were made the subject of the study. All the measurements were made from a right parasternal long axis left ventricular outflow tract view and the parameters measured were: left ventricular dimensions, left ventricular function, left ventricular volumes, left atrial and aortic root diameter and mitral valve parameters. Data obtained were also compared with that available for other dog breeds. Significant correlation (P<0.05) with body weight was obtained for some of the left ventricular, atrial and mitral valve parameters, being strong for LAD, AOD, LVIDd, LVIDs, IVSd and IVSs (r>0.5); moderate for LVPWd, LVPWs, EPSS, EF Slope and SV (r=0.3 to 0.5); weak for EDV and ESV (r<0.3). Non-significant effect of gender was seen on all the echocardiographic parameters. However, some of the parameters had a significant breed effect. It is expected that the obtained data will be valuable for the progress of studies on small animal cardiology.
Journal title :
Iranian Journal of Veterinary Research (IJVR)
Journal title :
Iranian Journal of Veterinary Research (IJVR)