• Title of article

    Isothermal P, x, y data for the argon + carbon dioxide system at six temperatures from 233.32 to 299.21 K and pressures up to 14 MPa

  • Author/Authors

    Coquelet، نويسنده , , C. and Valtz، نويسنده , , A. and Dieu، نويسنده , , F. and Richon، نويسنده , , D. and Arpentinier، نويسنده , , A. P. M. Lockwood، نويسنده , , F.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    6
  • From page
    38
  • To page
    43
  • Abstract
    Isothermal vapor–liquid equilibrium data have been measured for the argon + carbon dioxide binary system at 6 temperatures from 233.32 to 299.21 K, and at pressures from 1.5 to 14 MPa. The triple point temperature of CO2 (216.58 K) is higher than the Ar critical temperature (150.86 K). As a consequence, working at temperatures higher than the triple point temperature of CO2, it is not possible to define the vapor pressure of pure Ar and the vapor–liquid equilibrium isotherms will always present a mixture critical point. VLE data have been measured using the “static–analytic” method, taking advantage of two pneumatic capillary samplers (Rolsi™, Armines’s patent) designed and developed in the CEP/TEP laboratory. The isothermal P, x, y data are well represented with the Peng–Robinson equation of state combined with Mathias–Copeman alpha function and the Wong–Sandler mixing rules involving the NRTL model.
  • Keywords
    Isothermal VLE data , argon , High pressures , CO2 , Supercritical gas solubility , critical point , Phase diagram determination , MODELING
  • Journal title
    Fluid Phase Equilibria
  • Serial Year
    2008
  • Journal title
    Fluid Phase Equilibria
  • Record number