Title of article :
Isobaric heat capacity measurements of liquid HFE-7200 and HFE-7500 from 245 to 353 K at pressures up to 15 MPa
Author/Authors :
Zheng، نويسنده , , Yuxin and Gao، نويسنده , , Hui and Chen، نويسنده , , Qiang-qiang Meng، نويسنده , , Xianyang and Wu، نويسنده , , Jiangtao، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
7
From page :
56
To page :
62
Abstract :
An adiabatic flow calorimeter was developed for the measurement of the isobaric heat capacity of pure liquids and their mixtures, which could be used over the temperature range of (243–393) K and at pressure up to 20 MPa. The apparatus has been validated by measuring the isobaric heat capacity of pure water at different temperatures and pressures. With the flow calorimeter, the isobaric heat capacity of HFE-7200 (1-ethoxy-1,1, 2,2,3,3,4,4,4-nonafluorobutane, CAS Registry Number: 163702-05-4) and HFE-7500 (3-ethoxyperfluoro(2-methylhexane), CAS Registry Number:297730-93-9) were measured in the termperature range from (245 to 353) K and pressure range from (0.1 to 15) MPa. The expanded uncertainty with a level of confidence of 0.95 (k = 2) of the isobaric heat capacity measurement was estimated to be within ±2%, and the repeatability of the experimental data was better than ± 1%.
Keywords :
HFE-7200 , Flow calorimeter , HFE-7500 , heat capacity
Journal title :
Fluid Phase Equilibria
Serial Year :
2014
Journal title :
Fluid Phase Equilibria
Record number :
1990018
Link To Document :
بازگشت